4-12

Chapter 4 Handler Setup

A

DRS

D

ESCRIPTION

ROM

RAM

O

PTIONS

C

OMMENTS

00E7

Pickup 1000

0

30 to 39

For Type 5B CO Kits only
Sets 1000’s digit, Home sensor to pick up point

00E8

Pickup 100

9

30 to 39

For Type 5B CO Kits only
Sets 100’s digit, Home sensor to pick up point

00E9

Pickup 10

0

30 to 39

For Type 5B CO Kits only
Sets 10’s digit, Home sensor to pick up point

00EA

Pickup 1

0

30 to 39

For Type 5B CO Kits only
Sets 1’s digit, Home sensor to pick up point

00EB

T Site 10000

0

30 to 39

For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to Test Site point

00EC

T Site 1000

5

30 to 39

For Type 5B CO Kits only
Sets 1000’s digit, Home Sensor to Test Site point

00ED

T Site 100

0

30 to 39

For Type 5B CO Kits only
Sets 100’s digit, Home Sensor to Test Site point

00EE

T Site 10

0

30 to 39

For Type 5B CO Kits only
Sets 10’s digit, Home Sensor to Test Site point

00EF

T Site 1

0

30 to 39

For Type 5B CO Kits only
Sets 1’s digit, Home Sensor to Test Site point

00F0

Exit 10000

1

30 to 39

For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to exit point

00F1

Exit 1000

0

30 to 39

For Type 5B CO Kits only
Sets 1000’s digit, Home sensor to exit point

00F2

Exit 100

8

30 to 39

For Type 5B CO Kits only
Sets 100’s digit, Home sensor to exit point

00F3

Exit 10

0

30 to 39

For Type 5B CO Kits only
Sets 10’s digit, Home sensor to exit point

00F4

Exit 1

0

30 to 39

For Type 5B CO Kits only
Sets 1’s digit, Home sensor to exit point

00F5

Password On/Off

00

00, FF

Sets the controller password protection for the handler.
Set to 00, password is required to make changes to the
handler set up. Set to FF, password is not required.
F

ACTORY SET PASSWORD IS

: 789.

00F6

Check I-Lock

00

00, FF

FF = No Check
00 = Will check optional CO Kit cover interlock, will stop
the handler if the interlock is open.

00F7

Plunge Power

44

40, 44

40 = Standard Power.
44 = More Torque.
Standard Power cuts power to the coils when the Z-
motor stops. This is a power-saving function. More
Torque leaves full power on the coils when the Z-motor
stops.
For Type 4 Plunge to Board CO Kits Only

00F8

Plunge Delay

0A

00 to FF

Time delay between each step during Z-motor plunge.
Delay may be set in .25 millisecond increments: 01 =
.25 msec delay. 02 = .50 msec delay, etc.
For Type 4 Plunge to Board CO Kits Only

00F9

Soft Plunge Step

0A

00 to FF

Sets the number in HEX of full steps in this special
reduced-impact plunger sequence. F

OR EXAMPLE

: 0A = 10

full steps. If the handler is set to Half Step (see below)
this number is automatically doubled. DO NOT USE
MORE THAN 100 STEPS.
For Type 4 Plunge to Board CO Kits Only