Chapter 5 Diagnostics

;

;

;

;

Tube Switch, 1 Through 8

__________________________________________________________________

This diagnostic tests port B6, located on PCB #5000-A89, PAL A89-8.
Please refer to drawing #6000-517 for sensor wiring details.

TO ENTER THIS CHECK:

Handler displays DIAGNOSTICS
Press the [1] key.

Handler displays SENSOR CHECK
Press the [4] key.

Handler displays TUBE _ _ _ _ _ _ _ _ if all output tubes are removed from the handler. If numbers are
displayed, they indicate:

1 = Tube 1 Switch
2 = Tube 2 Switch
3 = Tube 3 Switch
4 = Tube 4 Switch
5 = Tube 5 Switch
6 = Tube 6 Switch
7 = Tube 7 Switch
8 = Tube 8 Switch

NOTE: The handler will display TUBE CLEAR WORK for two seconds whenever any of the output tubes
is removed. The message may flash when inserting a new tube. This is an indication that the "tube count
clearing" pulse is being received by the handler’s CPU. If this signal is not present, check pin 2,
PAL A89-10, on PCB #5000-A89. This pin should pulse whenever any tube is removed from the handler.

Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.

Press the [Enter] button to EXIT this diagnostic check.