Exatron 3000b – Extron electronic 3000B User Manual

Page 76

Advertising
background image

Exatron 3000B

www.exatron.com

4-10

Chapter 4 Handler Setup

A

DRS

D

ESCRIPTION

ROM

RAM

O

PTIONS

C

OMMENTS

00BF

FF

00C0

Sort 1 Bins 1-8

EF

00 to FF

Input Sort 1 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C1

Sort 2 Bins 1-8

10

00 to FF

Input Sort 2 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C2

Sort 3 Bins 1-8

10

00 to FF

Input Sort 3 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C3

Sort 4 Bins 1-8

10

00 to FF

Input Sort 4 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C4

Sort 5 Bins 1-8

10

00 to FF

Input Sort 5 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C5

Sort 6 Bins 1-8

10

00 to FF

Input Sort 6 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C6

Sort 7 Bins 1-8

10

00 to FF

Input Sort 7 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C7

Sort 8 Bins 1-8

10

00 to FF

Input Sort 8 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.

00C8

Pick Up Step
1000

1

30 to 39

Label Pick up “1000” step setting 3000BL only

00C9

Pick Up Step 100

0

30 to 39

Label Pick up “100” step setting 3000BL only

00CA

Pick Up Step 10

1

30 to 39

Label Pick up “10” step setting 3000BL only

00CB

Pick Up Step 1

2

30 to 39

Label Pick up “1” step setting 3000BL only

00CC

Apply Step 100

4

30 to 39

Label Apply “100” step setting 3000BL only

00CD

Apply Step 10

3

30 to 39

Label Apply “10” step setting 3000BL only

00CE

Apply Step 1

7

30 to 39

Label Apply “1” step setting 3000BL only

00CF

Label Que

01

00 to 19

Sets the number of labels printed on power up. Setting
depends on version of 3000BL. In most cases set to 01,
prints only 1 label. 3000BL only

00D0

Add Label

FF

00, AA,
FF

For 3000BL only
00 = Test and Label in one operation
FF = Test only, skip the label site
AA = Label only, no test

00D1

Bit Check

00

00, FF

For P

ROGRAMMER

RS-232 Interface only.

Performs Illegal Bit Test at the start of the programming
cycle.
00 = Bit Check ON. (Data I/O)
FF = Bit Check OFF. (Bytek)

00D2

Interface Type

26

23, 25,
26

Sets default interface to be used by the handler.
23 = P

ROGRAM

RS-232 Interface (Data I/O, Bytek)

25 = E

XATRON

RS-232 Interface

26 = H

ANDLER

P

ORT

Interface

00D3

P/V/L

02

02, 04,
08

For P

ROGRAMMER

RS-232 Interface only.

Selects Program, Verify, or Load Master operation.
02 = Program. 04 = Verify. 08 = Load Master.

00D4

Plunge
Steps1000

0

30 to 39

For Plunge to Board Type 4 Changeover Kits. Sets the
1000s digit of the Z-motor plunge to contact steps. Set
as ASCII Number.

00D5

Plunge Steps 100

3

30 to 39

For Plunge to Board Type 4 Changeover Kits. Sets the
100s digit of the Z-motor plunge to contact steps. Set
as ASCII Number.

Advertising