Diagnostics quick reference, Diagnostics quick reference -2 – Extron electronic 3000B User Manual

Page 81

Advertising
background image

Exatron 3000B

www.exatron.com

5-2

Chapter 5 Diagnostics

You may also enter Diagnostics Mode during most automatic device jam-clearing cycles, when the output
tube cover LEDs are flashing. If Diagnostics Mode is accessed during a jam, the handler will exit its
automatic jam-clearing cycle and enter Diagnostics. When Diagnostics procedures are complete, the
handler will return to its previous place in the program, upon exiting Diagnostics. In most cases, if the jam
is cleared during Diagnostics, the handler will also automatically restart after returning from Diagnostics.

NOTE: On some custom machines there are more options available inside DIAGNOSTICS. See the
supplement at the end of this manual for all the functions available on your particular handler.

Diagnostics Quick Reference

↵↵

This symbol means:

Press

the

[Enter]

button

.

[DIAGNOSTICS] Enters DIAGNOSTICS Menu.

[1]

key = SENSOR CHECK, then:

[1]

key = SENSORS 0-7;, then:

1. PICKUP HEAD VACUUM;

↵↵

to return to SENSOR CHECK.

2. INDEX SENSOR;

↵↵

to return to SENSOR CHECK.

3. PART PRESENT AT PICKUP;

↵↵

to return to SENSOR CHECK.

4. Y MOTOR HOME;

↵↵

to return to SENSOR CHECK.

5. N/A;

↵↵

to return to SENSOR CHECK.

6. N/A;

↵↵

to return to SENSOR CHECK.

7. N/A;

↵↵

to return to SENSOR CHECK.

↵↵

To return to DIAGNOSTICS Menu.

[2]

N/A

[3]

SHUTTLE SENSORS.

Sensors 1-8 correspond to location of output shuttle as indicated by the red LED’s
on the blue output cover.

[4]

FULL TUBE.

Sensors 1-8 indicate if corresponding tube is full of completed parts.

[5]

TUBE.

Sensors 1-8 indicate if tube is present in the tube holder.

Advertising