Exatron 3000b – Extron electronic 3000B User Manual

Page 52

Advertising
background image

Exatron 3000B

www.exatron.com

3-10

Chapter 3 Interface Info

FIGURE 3-1

B

HANDLER INTERFACE PORTS DETAIL
HANDLER PORT SEE 5000-A89 FOR DETAILS
MATING CONNECTOR CINCH #57-30240

REMEMBER:

1. Use the 24-pin handler port.

2. All signals are TTL/CMOS compatible.

3. Opto-isolation is available as an optional feature except on the 2000B

Series Handlers. To obtain this feature for your Model 3000B or Model
5000 Handler, please specify your request at the time of placing your
handler order.

Additionally, all 3000B and 5000 Series Handlers may be upgraded to
opto-isolation in the field. To order this upgrade for an existing handler,
contact the E

XATRON

Sales Department and order PCB #5000-D76,

"Opto Isolation Interface/Light Pole Option PCB." Our toll-free telephone
number is 1-800-EXA-TRON.


4. The +5 volt output on the handler port (Pins 11, 23) is NOT to be used by or connected to

the tester, unless it is isolated at the tester.


5. Pins 12 and 24 are ground connections.

6. Refer to F

IGURE

3-2 following, for timing diagram.

For further timing/sort details, please refer to D

RAWING

#5000-F62.

Sort 1 1
Sort 2 2
Sort 3 3
Sort 4 4
Sort 5 5
Sort 6 6
Sort 7 7

Sort 8 8

2

nd

Start 9

Start Test Pulse 10

HandlerVcc +5VDC 11

Handler Ground 12

13 Input 9 EOT
14 Not

Used

15 Not

Used

16 Not

Used

17 Output

8

18 Output

7

19 Output

6

20 Output

5

21 Output

4

22 Start Test Level
23 HandlerVcc

+5VDC

24 Handler

Ground

NOTE: NEVER CONNECT
TESTER Vcc TO
HANDLER Vcc

Advertising