All motor check: shuttle motor check, All motor check: shuttle motor check -14, Exatron 3000b – Extron electronic 3000B User Manual

Page 93

Advertising
background image

Exatron 3000B

www.exatron.com

5-14

Chapter 5 Diagnostics

;

;

;

;

ALL MOTOR CHECK: Shuttle Motor Check

_______________________________________________________

This diagnostic tests input port C4, output port C4, C9, located on PCB #5000-397, PAL 397-3, U7.

TO ENTER THIS CHECK:
Handler displays DIAGNOSTICS
Press the [4] key.

Handler displays ALL MOTOR CHK
Press the [1] key.

Handler displays SORT MOTOR CHK

NOTE: The handler's output cover LEDs will indicate the current location of the shuttle. The correct
pattern for an empty shuttle at each output bin is as follows:

LED 1 2 3 4 5 6 7 8

BIN

1

{ } { { { { { {

2

} { } { { { { {

3

{ } { } { { { {

4

{ { } { } { { {

5

{ { { } { } { {

6

{ { { { } { } {

7

{ { { { { } { }

8

{ { { { { { } {

}

Indicates flashing LED

{

Indicates LED turned off

Press the [1] key: "1 LEFT STEP." The Shuttle will move one tube to the left.
Press the [2] key: the handler will display the current motor settings in RAM. This display is helpful when
trying to increase the motor's speed.
Press the [3] key: "1 RIGHT STEP." The Shuttle will move one tube to the right.
Press the [4] key: "2 LEFT STEPS." The Shuttle will move two tubes to the left.
Press the [6] key: "2 RIGHT STEPS." The Shuttle will move two tubes to the right.
Press the [7] key: "JOG LEFT." The Shuttle will move one step to the left, about .006".
Press the [8] key: the shuttle will try to automatically center itself at Home bin #5.
Press the [9] key: "JOG RIGHT." The Shuttle will move one step to the right, about .006".
Press the [0] key: "MOTOR OFF." The Output Sort Motor is now off.

Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.

Press the

[Enter]

button to EXIT this diagnostic check.