Chapter 4 Handler Setup

A

DRS

D

ESCRIPTION

ROM

RAM

O

PTIONS

C

OMMENTS

00B3

FF

00B4

Gate Closed
Delay

02

00, FF

Delay to allow gate to close on PLCC Type 4 CO kits.
Counts down in HEX in 10 msec steps

00B5

L Apply Delay

0A

00, FF

Adds a delay after the label has been detected by the
vacuum on the label pick up head. Time to allow the
label to be fully picked up by the pick up head.
Counts down in Hex in 10 msec steps.

00B6

Shuttle Delay

10

00 to FF

Delays shuttle solenoid being turned off after device has
exited the shuttle into the output tube. Allows more time
for device to completely exit the shuttle.
Counts down in HEX in 10 msec steps.

00B7

FF

00B8

XTAL SMD Size

00

00 turns this option off
For Type 5B CO Kits Only, XTAL Devices only
50 = Sets the handler to run CA devices
51 = Sets the handler to run JA devices
52 = Sets the handler to run JC devices

00B9

Label Yes/No

00

Turns on all of the label apply software. Handler must
be a 3000BL.
00 = Turns label option OFF
01 = Turns label option on, label Sort 1 only
02 = Turns label option on, label Sort 2 only
….08, Sort/Label apply HEX decode

00BA

Label Out Delay

05

Adds delay to DUT exiting the label site, more time for
the stop pin to remain open. For 3000BL handlers only

00BB

Stop-Fail Sort

FE

00 to FF

Tells the handler which sort(s) to stop the system upon
Fail from tester.
00 = No stop on fail
FE = Stop on fail, all sorts EXCEPT bin 1
02 = Stop on fail, sort 2 only

00BC

Double Test Sort

00

00 to FF

Tells the handler which test sorts to double test if
desired.
00 = Double Test is OFF for all sorts.
FE = Double Tests all sorts except Sort 1
02 = Double test sort 2 only

00BD

Send H on Retest

FF

00, AA,
FF

Sets the handler to send the ASCII character “H” to the
tester at the start of each retest cycle, as it does at the
start of each first test cycle to establish communication.
This may be used for certain device count applications.
FF = Send H on test, send H on retest
00 = Send H on test, none on retest
AA = Never send H test or retest

00BE

SOL Shut Down

00

00, FF

00 = Handler will automatically shut off all solenoids
after 30 seconds of inactivity. Recommended for
handlers using solenoids in their CO Kits. Will prevent
some “melt downs”.
FF = Handler will leave Solenoids in active state until the
operator intervenes.