Extron electronic 3000B User Manual

Page 84

Advertising
background image

Exatron 3000B

www.exatron.com

5-5

Chapter 5 Diagnostics

[2]

SERVO MOTOR CHECK;

↵↵

to return to ALL MOTOR CHECK.

[1] Move to Pickup Site.
[2] Move to Test Site
[3] Move to Exit Site.
[4] Set Pickup Location = _ _ _ _
[5] Set Test Site Location = _ _ _ _
[6] Set Exit Site Location = _ _ _ _

Enter the location in steps starting with the ones position. Example entering 1234
Sets the location to 4,231 steps.

[6] Display Current Exit Site Location = _ _ _ _
[8] N/A
[9] Display Current Pickup Site Location = _ _ _ _

[Delete] key = Pickup Vacuum On/Off.
[Space] key = Air Blast On/Off.

↵↵

to return to ALL MOTOR CHECK.

↵↵

To return to DIAGNOSTICS Menu.

[5]

key = OCTO/INDEX CHK, then:

[1]

N/A

[2]

SHUTTLE GATE SOLENOID.

[3]

Input Sensors 1-8;

↵↵

to return to OCTO/INDEX CHK.

↵↵

To return to DIAGNOSTICS Menu.

Advertising