Exatron 3000B

www.exatron.com

5-16

Chapter 5 Diagnostics

;

;

;

;

ALL MOTOR CHECK: Octoloader Motor Check

__________________________________________________________________

This diagnostic tests input port C6, output port C6, C9 located on PCB #5000-397, PAL 397-5, U9.

TO ENTER THIS CHECK:

WARNING: VERIFY THAT THE OCTOLOADER IS EMPTY OF ALL DEVICES BEFORE USING THIS
DIAGNOSTIC.

Handler displays DIAGNOSTICS
Press the [4] key.

Handler displays ALL MOTOR CHECK
Press the [3] key.

Handler displays OCTO MOTOR CHK

Press the [1] key: 1 LEFT STEP. The Octoloader will move one tube to the left.

Press the [2] key: the handler will display the current motor settings in RAM. This display is helpful when
trying to increase the motor's speed.

Press the [3] key: 1 RIGHT STEP. The Octoloader will move one tube to the right.

Press the [4] key: 2 LEFT STEPS. The Octoloader will move two tubes to the left.

Press the [6] key: 2 RIGHT STEPS. The Octoloader will move two tubes to the right.

Press the [7] key: JOG LEFT. The Octoloader will move one step to the left, about .006".

Press the [9] key: JOG RIGHT. The Octoloader will move one step to the right, about .006".

Press the [0] key: MOTOR OFF. The Octoloader Motor is now off.

Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.

Press the

[Enter]

button to EXIT this diagnostic check.