Multi sort err, No bin time out, No output tubes – Extron electronic 3000B User Manual

Page 115: No response, No selection, No sort error, No tubes or full, O.k. to run, Octo motor chk, Exatron 3000b

Advertising
background image

Exatron 3000B

www.exatron.com

6-14

Chapter 6 Display Dictionary

MULTI SORT ERR

The handler is at the end of the test cycle. More than one sort command from the tester has been
received. The output cover LEDs will flash the sorts which were received by the handler.

Check whether your tester is working correctly. Check your interface cables for short-circuited
connections.

Press the [Enter] button to ISSUE NEW START and to clear the handler's input latch. If you are using an
E

XATRON

LED Checker as a simulator, make sure that only DIP switch #1 is turned ON.

NO BIN TIME OUT

The handler has a timer which runs during testing. This timer can be set to desired length in the handler's
RAM. If no bin signal is received from the tester before the timer "times out," the handler will turn off all
solenoids and display this message.

Press the [Enter] button to Restart the test, or

Press the [Clear] button to Abort the test and flush the device in the test site.

NO OUTPUT TUBES

The handler is trying to sort a device to an output tube, but no tubes are available. Check the handler's
output cover and insert an empty tube at any output with a flashing output cover LED.

NO RESPONSE

The handler is using the E

XATRON

RS-232 Interface and is waiting to receive a control code over the RS-

232 port from the tester.

NO SELECTION

Indicates that the handler controller button you have pushed is a not-used option.

NO SORT ERROR

The handler is trying to bin a device, but no End Of Test sort has been received. Check the tester/PC’s
set-up data to verify whether the handler sorts and handler bins are correctly set up.

Press the [Enter] button to skip past this error and try again.

NO TUBES OR FULL

The handler is waiting to sort a device to an output tube, but the tube is full or missing. Check the output
cover LEDs and insert an empty tube at any outputs with a flashing output cover LED.

O.K. TO RUN ? *

A number from 1 to 8 will be displayed in place of the asterisk shown above.

The handler has just exited a jam-clearing cycle. The operator must press the [RUN] button or the
[Enter] button to continue.

The number displayed with O.K. TO RUN ? indicates where the stop occurred in the handler's operation.

OCTO MOTOR CHK

Please refer to the Diagnostics/All Motor Check section in Chapter 5 of this manual.