Chapter 4 Handler Setup

A

DRS

D

ESCRIPTION

ROM

RAM

O

PTIONS

C

OMMENTS

00D6

Plunge Steps 10

4

30 to 39

For Plunge to Board Type 4 Changeover Kits. Sets the
10s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.

00D7

Plunge Steps 1

6

30 to 39

For Plunge to Board Type 4 Changeover Kits. Sets the
1s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.

00D8

2

nd

Start Width

00

00 to FF

Sets the width of an available second start pulse to be
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2

nd

Start

feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S

EE

I

NTERFACE

C

HAPTER FOR FURTHER

DETAILS

.

00D9

2

nd

Start Delay

00

00 to FF

Sets a time delay before the handler sends an available
second start pulse to the tester. Counts down in HEX in
1 millisecond steps. The second start pulse feature is
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2

nd

Start

feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S

EE

I

NTERFACE

C

HAPTER FOR FURTHER

DETAILS

.

00DA

Soak Time 1.0 S

0

30 to 39

Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 1.0 second digit.

00DB

Soak Time 0.1 S

0

30 to 39

Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 0.1 second digit.

00DC

Label Size

04

00 to 06

Sets default label size
01 = 300 DIP
02 = 600 DIP
03 = 20 PLCC
04 = 28/32 PLCC
05 = 44 PLCC
06 = 5 x 7 LCC

00DD

300 DIP V Delay

06

00, 30

Sets label print to vacuum on delay for 3000BL

00DE

600 DIP V Delay

20

00, 30

Sets label print to vacuum on delay for 3000BL

00DF

20 PLCC V Delay

0A

00, 30

Sets label print to vacuum on delay for 3000BL

00E0

28/32 V Delay

15

00, 30

Sets label print to vacuum on delay for 3000BL

00E1

44 PLCC V Delay

19

00, 30

Sets label print to vacuum on delay for 3000BL

00E2

5 x 7 V Delay

10

00, 30

Sets label print to vacuum on delay for 3000BL

00E3

FF

00E4

FF

00E5

5B Electronics

FF

5B, FF

Sets the handler to do self tests on handlers equipped
with Type 5B electronics, (Extra RS-232 port)
FF = No 5B checks

00E6

Pickup 10000

0

30 to 39

For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to pick up point

Advertising