Octo/index check: input sensor check, Octo/index check: input sensor check -18 – Extron electronic 3000B User Manual

Page 97

Advertising
background image

Exatron 3000B

www.exatron.com

5-18

Chapter 5 Diagnostics

;

;

;

;

OCTO/INDEX CHECK: Input Sensor Check

_______________________________________________________

This diagnostic tests port B2, located on PCB #5000-A89, PAL A89-10.

TO ENTER THIS CHECK:

Handler displays DIAGNOSTICS
Press the [5] button.

Handler displays OCTO/INDEX CHK
Press the [3] button.

Handler displays INPUT 8 if the handler is empty, and the octoloader is at the right hand stop.

1 = Not used
2 = Not used
3 = Not used
4 = Not used
5 = OPTIONAL: Fiber optic test site sensor

∗∗∗∗

6 = Top of rail sensor
7 = Octo/rail gap sensor
8 = Octoloader right hand stop limit switch

∗∗∗∗If this feature, which detects device in test site, is not functional:

1. The on/off ROM address listing may be required. Please contact the E

XATRON

factory for assistance.

2. Verify that the switch on the sensor controller, part number E3X-A11, is set with L-ON and D-ON.

3. The front panel PCB, part number 5000-A89, may require a PAL update. Please contact the

E

XATRON

factory for assistance.

Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.

Press the [Enter] button to EXIT this diagnostic check.