5020A

Users Manual

6-28

DATa:DSTatistics:RECord:ETIMe? [<num>]

Returns the daily statistics recording end time.
Example: DAT:DST:REC:ETIM?
Response: 23,59,59
The <num> parameter specifies the daily statistics record number. If none is specified,

record 1 is assumed. The response is returned in the format, <hour>,<minute>,<second>.

DATa:DSTatistics:RECord:FIND? (<year>,<month>,<day>)

Returns the daily statistics record number for the given date.
Example: DAT:DST:REC:FIND? 2003,9,13
Response: 25
If no daily statistics were recorded for the given date a 0 is returned.

DATa:DSTatistics:RECord:VALue? <num>,<chn>,<type>

Returns the daily statistics statistical calculation.
Example: DAT:DST:REC:VAL? 1,1,1
Response: 25.559,0.733,23.097,27.203,4.106,43200,17.16,0
The <num> parameter specifies the daily statistics record number. The <chn> parameter

specifies the channel (1 or 2). The <type> parameter specifies the statistic: average (1),

standard deviation (2), minimum (3), maximum (4), spread (5), maximum rate (7), or

alarm count (8). Temperature values are in the current temperature unit, C of F.

DATa:RECord:CLEar

Clears all recorded measurement data.
Example: DAT:REC:CLE
This command is password protected. To access this command when the

SYST:PASS:REC is enabled, the password must be successfully entered using the

SYST:PASS:CEN <pass> command (see Password Commands).

DATa:RECord:FEED:RHUMidity<chn>?

Returns the state of the humidity recording enable for the specified channel.
Example: DAT:REC:FEED:RHUM1?
Response: 1
The RHUMidity suffix <chn>, specifies the channel (1 or 2). A value of 1 is returned if

the humidity recording for the specified channel is enabled. A value of 0 is returned if the

humidity recording for the specified channel is disabled.

DATa:RECord:FEED:RHUMidity<chn> <bool>

Sets the state of the humidity recording enable for the specified channel.
Example: DAT:REC:FEED:RHUM1 0
The RHUMidity suffix <chn>, specifies the channel (1 or 2). The <bool> parameter turns

the humidity recording for the specified channel on (1 or ON) or off (0 or OFF). This

command may be password protected (see Password Commands).