9-15

Alarms

Alarm Examples

9

Alarm Examples

The following are six examples for alarms and alarm groupings. Each provides a
picture of the

Current Module Alarms

dialog box and a description of what will

occur when for the alarms are triggered.

Alarm Example, Utilization

Figure 9-6. Alarm Example, Utilization

This simple example shows an alarm group consisting of one MAC Layer alarm for
Utilization. This alarm samples network traffic at five-second intervals. When the
absolute, rising value of 50 (percent utilization) is exceeded, Surveyor issues an
audible alarm and displays a message in Surveyor’s message window.