Crc frame counter, Crc frame counter -104 – Finisar Surveyor User Manual

Page 308

Advertising
background image

10-104

Surveyor

User’s Guide

CRC Frame counter

Counter

The CRC Frame counter increments when a frame has a CRC error and is greater
than 63 bytes in length. A count of all CRC Frames is included in the Bad Frames
counter. The CRC Frame counter is used for Expert Alarms.

Expert Symptom

CRC Frame events are automatically logged as expert symptoms. The

Symptom

Summary

field contains the following information:

CRC error with more than 63 bytes

Diagnostic Details

__________________________________________________________________

Problem Description:

A packet with more than 63 bytes of data and a CRC error has been received.

__________________________________________________________________

Probable Cause(s):

1. The network is overloaded, resulting in too many collisions.
2. A faulty hub/switch/router device.
3. An end station may have a faulty network interface card.
4. A protocol analyzer has been transmitting error packets.

__________________________________________________________________

Recommended Action(s):

1. Find out the source device and fix the problem.