Physical errors, Physical errors -118 – Finisar Surveyor User Manual

Page 322

Advertising
background image

10-118

Surveyor

User’s Guide

Physical Errors

Counter

The Physical Errors counter increments when a change in the number of total MAC
physical errors per second exceeds a threshold. Physical errors include CRC/
alignment errors, dropped events, collisions, jabbers, oversize packets, undersize
packets, and fragments. A count of all instances where the threshold is reached
displays in the Overview counters of Expert View.

Expert Symptom

Physical Error events are automatically logged as expert symptoms. The

Symptom

Summary

field provides information about the rate of change for total MAC

physical errors. For example:

Rate of change of Errors=450

The threshold value for this symptom can be changed. The default threshold is a

delta of 400 physical error packets per second.

Diagnostic Details

__________________________________________________________________

Problem Description:

The error threshold has been exceeded for this segment, resulting in a MAC
Physical Errors symptom.

__________________________________________________________________

Probable Cause(s):

1. The network is overloaded.
2. A faulty hub/switch/router device.
3. A hub may have been incorrectly used.

Ex:, an uplink port may have been used as a data port.

4. An end station may have a faulty network interface card.

__________________________________________________________________

Recommended Action(s):

1. Restart the capture after setting up a filter to capture error packets only.
2. Based on the capture, isolate the device that is in error and fix the problem.