Sip call field descriptions -23 – Finisar Surveyor User Manual

Page 357

Advertising
background image

11-23

Multi-QoS

Field Descriptions for Call Details

11

Table 11-9. SIP Call Field Descriptions

Field Name

Description

FID

Frame ID of the first frame from which the conversation was detected. The
the frame ID of the first INVITE message.

Caller

SIP URL or other URI of the caller. The addr-spec in the “From” parameter.

Caller Name

Display name of the caller. The display name in the “From” parameter, if it
exists.

Caller Tag

The tag of “From”, if it exists.

Caller Address

The IP address of the initiator of the call.

Start Time

Time at which the call was started, i.e. the time of the first INVITE message
of the call.

Stop Time

Time at which the call was complete.

Setup Time (ms)

Time that was taken for the call to be setup. This is the duration from
“INVITE” to the 180 or 183 (ringing) response if available, or to the 200
response otherwise. If none of these responses are received, the field
value is set to “Unknown”.

Call-ID

Globally unique ID to identify a SIP call.

Callee

SIP URL or other URI of the callee. The addr-spec in the “To” parameter.

Callee Name

Display name of the callee. The display name in the “To” parameter, if it
exists.

Callee Tag

The tag of “To”, if it exists.

Callee Address

The IP address of the receiver of the call.

SIP Version

The version of SIP being used.

Response Code

The response code number from the callee.

Call Status

Status of the call. An active call has the status of “Setting up” or “Set up
complete”, and a complete call has the status of “Set up failed”, “Aborted”,
“Complete”.