background image

10-115

Expert Features

MAC Layer

10

Oversized Frame

Counter

The Oversize Frame counter increments when a frame has a CRC error and is
greater than 1518 bytes in length. A count of all Oversize Frames is included in the
Bad Frames counter that displays in the Overview counters of Expert View. The
Oversize Frame counter is used for Expert Alarms.

Expert Symptom

Oversized Frame events are automatically logged as expert symptoms. The

Symptom Summary

field contains the following information:

Oversized frame has more than 1518 bytes

Diagnostic Details

__________________________________________________________________

Problem Description:

A packet with more than 1518 bytes of data has been received.

__________________________________________________________________

Probable Cause(s):

1. A faulty hub/switch/router device.
2. An end station may have a faulty network interface card.
3. A protocol analyzer has been transmitting error packets.

__________________________________________________________________

Recommended Action(s):

1. Find out the source device and fix the problem.