This section briefly explains circuits and how they operate.

5.3.1

System configuration

The Fujitsu MB90706 MPU receives data and commands from the host computer and controls the printing

mechanism (Figures 5.17 and 5.18).

Figure 5.17 System configuration

Host
computer

Control
panel

Interface
controller

(RS-423)

MB90706

Power supply
unit

Sensors

Driver
circuit

Printing
mechanism

Printer control board
(Main board)

Printer

Interface
controller
(Centronics)

MBCU20050