4-17

(6) Power supply and fuse replacement

Removal

1.

Remove the fuse from the power supply, if necessary.

2.

Disconnect AC and CNPW connectors.

3.

Remove the four screws (three screws for LA36W) then remove the power supply. The rod and its securing

screw are not used for LA36W.

Installation

Install the power supply and fuse in reverse order of removal.

Notes:

For LA36N only; before connecting the CNPW connector to the corresponding connector on the control board

(ROM board), be sure to turn the CNPW connector twice to twist the cable, fix the cable by the clamp, and wind

the cable once around the rod. If the cable wires are bound with a tie, cut the tie before winding the cable.

Fuse (*)

AC connector

Rod

(LA36N only)

CNPW connector

power supply

Rod

CNPW connector

Power supply

Clamp of rod