Genicom MatrixPrinter LA36 User Manual

Page 29

Advertising
background image

3-8

Connect the interface cable.

Replace the interface cable.

See page 3-5, DC voltage check.

Use the correct protocol.

Use the correct baud rate.

Use the correct data length.

Use the correct data format.

No

Yes

No

Yes

No (Centronics)

Yes

No

Yes

No

Yes

No

Yes

Yes

No

No printing online

Is the interface cable connected?

Is the interface cable OK?

Is the RS-423 interface used?

Is the selected protocol OK?

Is the selected baud rate OK?

Is the selected data length OK?

Is the selected data format OK?

See page 3-5, DC voltage check.