Alarm Routing Client Group Assignment Dialog Box

This dialog box allows you to select and assign Client Groups for this routing record. Only Client Groups
in the operator’s facilities are available for assignment by this operator.

Select, and then click the right arrow to assign an available Client Group.

Select, and then click the left arrow to unassign a Client Group.

Click OK to close this dialog box and display the results in the Routing, Client Groups windowpane.

Alarm Selection Tab

Alarm Notifier Form
The Alarm Selection tab allows you to assign alarms in this operators’ facility that will trigger an e-mail
message.
Assigned Alarms:
This windowpane displays any previously assigned alarms.
Assign Alarms
Click Assign Alarms to display the

Alarm Assignment

dialog box that allows you to select specific alarms

that will trigger e-mail notifications. Click OK and the selected alarms will display in the Assigned Alarms
windowpane.
Transaction Type
Select one or both transaction types that will trigger an e-mail alarm notification.

Alarm: E-mail notification is sent at onset of the alarm.

Reset: E-mail notification is sent when an alarm is reset.

By default, no type is selected when you create a new Alarm Notifier record. A transaction type must be
selected in order to save this record.

Alarm Sense Time

This form allows you to add or edit the link between an event and an alarm sense time. The event
determines when and to what value the sense times for all alarms in the group are changed.

Event: Select an event from the drop-down list. If there are no events listed, you will need to
configure events using the Event Schedule Form.

New time: Select or enter a sense time. The value is in seconds and indicates the delay
before triggering an associated digital output or sending in a Secure Perfect alarm if the DI
type is Alarm. This number tells the system how many seconds to wait after sensing the input
has changed to Active State. Enter

00

to immediately send the transaction to the host,

notifying the host of a state change. Increase the Sense Time entry if using noisy or
chattering contacts.

Example: This value could indicate the delay time, in seconds, that elapses between the time a door
contact is broken and the time the output and alarms are triggered. If door contact is re-established
before the sense time elapses, the alarm would not come in to Secure Perfect and the output would not
activate.