Reader/digital output tab – GE v6 User Manual

Page 228

Advertising
background image

Secure Perfect 6.1.1 User Manual

226

Reader/Digital Output Tab

Manual Control Form
Manually lock or unlock doors and turn on or off DO (digital output) points, depending on the current
operator’s

facilities

and

permissions

.

Schedules override manual changes unless Indefinite Unlock has been selected. Micros will always

run schedules defined previously in its database. Therefore, if there was a schedule set to be in effect at
the current time, the manual change would be overridden and the schedule would be enforced.

Select micro

A micro must be selected before the system searches and displays results in the list box.

•

All displays all the digital outputs of the type selected in the field Select DO type, found on all micros.

•

By Micro displays all the digital outputs of the type selected in the field Select DO type, found on a
selected micro. Click the drop-down list to display a list of micros.

Select DO type

•

If you select Reader, the windowpane displays the DO points available for the readers.

•

If you select Other, the windowpane displays Aux DOs (the two 2 DO relays available on a 2RP
board) and other DO points. Example DO points include lights, sirens, and door strikes that may be
connected to the micro.

Columns in Windowpane

•

Description: Description of the reader/DO in the database.

•

Micro: Micro on which the reader/DO is located.

•

On Time: Displays the On Time in the database. The On Time is the number of seconds this DO
remains in the active state when activated.

Set state to:

The names of the buttons change depending on the DO type (Reader or Other) selected.

If Reader is selected, click. . .

•

Duration Unlock: To unlock the selected door for the time specified in the On Time column.

•

Lock: To immediately lock the selected door.

•

Indefinite Unlock: To unlock the selected door. It will remain unlocked until you manually lock it by
clicking lock.

•

Sched. Override: To change the state of a door or DO, if you want a schedule to override its setting.
Example: Use Sched. Override to unlock a door if you want a schedule at a later time to lock this door.
If you don’t want the scheduler to lock your door, use the Indefinite Unlock selection.

If Other is selected, click. . .

•

On For Duration: Activates the selected DO for the time specified in the On Time column.

•

Off: Immediately deactivates the selected DO.

•

On Indefinite: Activates the selected DO, which will remain active until you manually turn it off by
clicking Off.

•

Sched. Override: Use this option to change the state of a DO if you want a schedule to override its
setting.

Purpose
Enter an explanation for locking/unlocking doors or activating/deactivating DO points. This field accepts
255 alphanumeric characters. These comments are written to the operator history file and display on the
Operator History Report, Purpose Field.