173

Floor Tab

Access Right Form
This tab allows you to configure controls for elevators and floors by assigning them to access rights.

Assigned elevators: This windowpane displays a list of the elevators assigned to the current
access right.

Assign Elevators: Click this button to display the

Elevator Assignment

dialog box and select

from a list of elevators available for assignment by this operator. If no elevators are listed,
check that the elevators have been configured on the Elevator Form.

Assigned floors: This windowpane displays the floors assigned to the current access right.

Assign Floors: Click this button to display the

Floor Assignment

dialog box and select from a

list of floors available for assignment by this operator. Only floors assigned to the selected
elevators will be available for assignment. If no floors are listed, verify that the floors have
been configured on the Floor Form.

Floor Tab

Floor Form
Use this tab to create a description for a floor

Description: Enter a description for the floor.

Floor Selection: Click the drop-down list of number to select a floor number.

Floor Tracking By Input

Define the floors available. Define a digital input (DI) and digital output (DO) for each floor. The DIs are
used for floor selection. Only DIs provided by the 20 DI board may be used for floor selection and each DI
may be used in only one elevator and mapped to only one floor. The DOs are used to control where the
elevator moves. Only DOs provided by the 16 DO board may be used and each digital output may only
be used in one elevator and mapped to one floor. A maximum of 32 floors can be supported.

Floor Tracking By Keypad

Define the floors available and define a digital output (DO) for each floor. The reader's keypad is used to
select the desired floor. Only DOs provided by the 16 DO board can be used. In addition, each DO may
be used in only one elevator and mapped to only one floor. The number of floors is limited by the number
of 16 DO boards that can be placed in the Micro/5-PX; the maximum is 4. Therefore, the maximum
number of floors available is 64 (4 boards x 16 DOs = 64 DOs).