201


Exit Request
Debounce

Enable this field to increase the sense time on all the Exit DIs (exit
requests). This field is useful if using noisy or chattering contact
interference in which you receive false exit requests.

Send Real
Time Digital
Output
Status

When this checkbox is selected, any digital output change-of-state is
reflected on the Alarm Graphics Viewer, in real-time status. This activity
is also recorded in Digital Ouput History.

Micro Flash and Micro Parameter Configuration

This dialog box displays only if the micro is online. There are three options:

View/Edit Parameter Info
Micro Parameter – Direct/Dialup
: This option is available for selection of a single micro. When
selected, the Micro Parameter Configuration screen displays and the configuration for the micro is
retrieved, allowing you to edit or change an existing setup such as micro address, IP address change,
or phone number changes. Once saved, the micro will reset and the new changes take effect.

If you change parameter block data through Secure Perfect, any Universal Badge Format (UBF)

data will be erased.

For example: If a M/5-PXN was originally configured as a direct serial micro during installation but
will now be a network micro, select the updated micro type and complete the network information.
Click OK. The micro will accept the changes, reset, then change the host information for this micro.
The Micro Parameter – Direct/Dialup tab allows you to change the connection type of the micro and
its Address, Idle Time, and DI res tolerance.
The Micro Parameter – Networking tab will display only if the system identified your micro as a
network micro and allows you to change the network parameters for the micro.

Micro Parameter – Badge Format: This tab opens to display the custom badge formats that are
currently in the micro. If there are no custom formats, the fields are empty. If a format in the database
does not match what is available in the micro, the window list displays a message ‘Unrecognized
Format.’ To change the badge format:

Magnetic stripe: Select the type of magnetic stripe format from the drop-down list.

Wiegand: Click

Assign formats

to display a list of available Wiegand badge formats from which

to choose and assign to this micro.

Clear formats in micro: Click to clear all custom badge formats from the micro. Badges
associated with those formats will no longer work.

If you change the badge format, any format that existed in the micro previously is replaced.

Start Flashing Micro(s)
This option will start flashing the selected micro(s) with the latest firmware. A dialog box will display
asking you to verify your request. The flashing process takes approximately two to three minutes; it
varies with amount of data that needs to be transmitted to the micro.

View/Edit Flash Files
Use this option ONLY when it is necessary to selectively flash an older version of firmware on a micro.
The Secure Perfect system automatically selects the latest version by default. The flashing process
takes approximately two to three minutes; it varies with amount of data that needs to be transmitted to
the micro. Click OK to begin the flash. When flashing is complete, the micro resets and requests a
database.

Micro/5 – PX and Micro/PX – 2000: The form opens with the latest .

efl

firmware file

displayed. Click the drop-down list to display and select an older firmware file.

Micro/5 – PXN and Micro/PXN – 2000: The form opens with the latest .

efl

network firmware

file displayed. Click the drop-down list to display and select an older network firmware file.

MicroPXNPlus and MicroPXNPlus2000: The form opens with the latest .

efl

network

firmware file displayed. Click the drop-down list to display and select an older network firmware
file.

Browse: Click to navigate to another media source or directory where firmware files reside.

Override Block Checking: Ignore this checkbox. This selection is for Customer Support use
only.