Secure Perfect 6.1.1 User Manual

194

M

Manual Control

Operations Menu
The Manual Control option opens the Manual Control Form that allows you to control:

DO (digital output) states for Door DOs and other DOs.

DI (digital input) states for Alarm DIs and other DIs.

Intrusion Zone states.

The shortcut key combination for Manual Control Form is CTRL+O.

Clicking this icon from the Secure Perfect toolbar can also access this option:

Manual Control Tab

Digital Output Form
Use this tab to manually set the state of a specified digital output.
Purpose
Enter the reason for manually changing the state of the specified digital output. The text entered here is
recorded in Operator History.
Set state to:

On for Duration: Click to set the selected digital output to its Active state for the On time
specified on the Digital Output tab.

On Indefinite: Click to set the selected digital output to its Active state until it is manually set
to its inactive state. The only way to turn it off is by selecting Off on this tab or Off on the
Manual Door/DO Control Form.

Off: Click to set the selected digital output to its inactive state.

Sched. Override: Use this option to change the state of the DO if you want the schedule to
override its setting. For example, use Sched. Override to unlock a door if you want a
schedule at a later time to lock this door. If you don’t want the scheduler to lock your door,
use the On Indefinite selection.

Advertising