Keypad Alarm Shunting

Reference Topics:

Both Read/Keypad Type Reader

Keypad Only Type Reader

Normal Type Reader


The keypad alarm shunting feature allows you to turn the monitoring of a group of alarms off or on using
the keypad. This can also be accomplished by setting up a schedule for an alarm group using a time
schedule.

Only reader board door inputs and 20DI board input points can be shunted from a keypad.

To identify a reader board door input, look for a default description that follows this format:

0001-1-01

Reader

.

To identify a 20DI board input point, look for a default description that follows this format:

0001-1-01

DI

.

Keypad Only Type Reader

Only reader board door inputs and 20DI board input points can be shunted from a keypad. (To

identify a reader board door input, look for a default description that follows this format: 01-1-01 Reader.
To identify a 20DI board input point, look for a default description that follows this format: 01-1-01 DI.)

Follow the steps below to shunt alarm groups within a micro connected to a keypad reader.

1. Click the start key on the keypad. The start key is labeled with either an asterisk <*> or a plus <+>

depending on the reader model.

2. Type one of the following:


0 - to turn monitoring off
1 - to turn monitoring on

3. Type the alarm group number (00 to 15) you want shunted.
4. Click the end key that is labeled with either a pound sign (#) or an <x>.
5. Click the start key on the keypad again.
6. Type your badge number on the keypad.
7. Click the end key (<#> or <x>).