5 - 99

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Reading the monitor value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Monitoring is carried out with a decimal display.

Monitor
value

Warning No.

For details of warning Nos.

(warning codes), refer to

Section 15.3 "List of warnings".

0

807

907

1007

1107

Monitoring is carried out with a decimal display.

Monitor
value

M code No.
(0 to 65535)

0

808

908

1008

1108

Monitoring is carried out with a decimal display.

Monitor value

Axis operation status

-2: Step standby

-1: Error

0: Standby

1: Stopped

2: Interpolation

3: JOG operation

4: Manual pulse generator operation

5: Analyzing

6: Special start standby

7: OPR

8: Position control

9: Speed control

10: Speed control in speed-position switching control

11: Position control in speed-position switching control

12: Position control in position-speed switching control

13: Speed control in position-speed switching control

0

809

909

1009

1109

Monitoring is carried out with a decimal display.

R

Monitor
value

Decimal integer
value

Unit conversion table

Actual
value

Unit conversion

R 10

n

)

)

Md.27

Current speed

Md.27

-2

mm/min

-3

inch/min

-3

degree/min

0

pulse/s

n

Unit

0

810
811

910
911

1010
1011

1110
1111