background image

Appendix - 51

MELSEC-Q

APPENDICES

Warning code comparisons

Warning type

Added

Deleted

Fatal warning

–

51, 52

Common

110

101, 105 to 108, 115

OPR, Absolute position restoration

–

–

JOG operation/Inching operation

–

–

Manual pulse generator operation

–

402

Positioning operation

516, 517, 518

–

I/F

–

–

Parameter

–

900

Warning whose name is changed: Warning code 512

A1SD75: Illegal external start function

QD75: Illegal external command function

: Refer to "Section 15.2 List of errors" and "Section 15.3 List of warnings" for details on error codes and warning codes.

(3) Input/output (X/Y) comparisons

Input (X)

Output (Y)

Name

A1SD75

QD75

Name

A1SD75

QD75

(QD75/A1SD75) READY

X00

X00

Axis 1 Positioning start

Y10

Y10

Axis 1 Start complete

X01

X10

Axis 2 Positioning start

Y11

Y11

Axis 2 Start complete

X02

X11

Axis 3 Positioning start

Y12

Y12

Axis 3 Start complete

X03

X12

Axis 4 Positioning start

–

Y13

Axis 4 Start complete

–

X13

Axis 1 Stop

Y13

Y04

Axis 1 BUSY

X04

X0C

Axis 2 Stop

Y14

Y05

Axis 2 BUSY

X05

X0D

Axis 3 Stop

Y1C

Y06

Axis 3 BUSY

X06

X0E

Axis 4 Stop

–

Y07

Axis 4 BUSY

–

X0F

Axis 1 Forward run JOG
start

Y16

Y08

Axis 1 Positioning
complete

X07

X14

Axis 1 Reverse run JOG
start

Y17

Y09

Axis 2 Positioning
complete

X08

X15

Axis 2 Forward run JOG
start

Y18

Y0A

Axis 3 Positioning
complete

X09

X16

Axis 2 Reverse run JOG
start

Y19

Y0B

Axis 4 Positioning
complete

–

X17

Axis 3 Forward run JOG
start

Y1A

Y0C

Axis 1 Error detection

X0A

X08

Axis 3 Reverse run JOG
start

Y1B

Y0D

Axis 2 Error detection

X0B

X09

Axis 4 Forward run JOG
start

–

Y0E

Axis 3 Error detection

X0C

X0A

Axis 4 Reverse run JOG
start

–

Y0F

Axis 4 Error detection

–

X0B

PLC READY

Y1D

Y00

Axis 1 M code ON

X0D

X04

Axis 1 Execution
prohibition flag

–

Y14

Axis 2 M code ON

X0E

X05

Axis 2 Execution
prohibition flag

–

Y15

Axis 3 M code ON

X0F

X06

Axis 3 Execution
prohibition flag

–

Y16

Axis 4 M code ON

–

X07

Axis 4 Execution
prohibition flag

–

Y13

Synchronization flag

–

X01

Use prohibited

Y00 to Y0F

Y1E to Y1F

Y01 to Y03
Y18 to Y1F

Use prohibited

X10 to X1F

X02, X03

X18 to X1F

: The ON/OFF statuses for READY are different between the QD75 and A1SD75.

Not READY/WDT error

READY

QD75

OFF

ON

A1SD75

ON

OFF