Melsec-q, 6 sequence program used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 236

Advertising
background image

6 - 16

MELSEC-Q

6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL

(For positioning data No. 1 <axis 1>)

No. 2 Positioning data setting program

<Positioning identifier>

Operation pattern: Positioning complete
Control system: 1-axis linear control (ABS)
Acceleration time No.: 1, deceleration time No.: 2

<Setting of positioning identifier>

<Setting of M code (9843)>

<Setting of dwell time (300ms)>

<(Dummy data)>

<

Setting of command speed (180.00mm/min)

>

<

Positioning address (412.6

m) setting

>

<

Setting of arc address (0.0 m)

>

<Setting of positioning data No. 1 to QD75>

Block start data of start block 0 (axis 1)

No. 3 Block start data setting program

For setting of points 1 to 5

Shape: Continued at points 1 to 4, ended at point 5
Special start instruction: Normal start at all of points 1 to 5
<Positioning data are already preset>

(Conditions)

[Setting of shape and start data No.]

<Setting of continue and start data No. 1>

<Setting of continue and start data No. 2>

<Setting of continue and start data No. 5>

<Setting of continue and start data No. 10>

<Setting of end and start data No. 15>

<Setting of block start data to QD75>