MELSEC-Q

12 CONTROL SUB FUNCTIONS

(2) Block start

At a block start, this function is valid for only the position control whose

operation pattern is "Positioning complete" at the point whose shape has

been set to "End". (Refer to Fig. 12.52.)

The following table indicates the operation of the deceleration start flag in the

case of the following block start data and positioning data.

Block start

data

Da.11

Shape

Da.12

Start data No.

Da.13

Special start

instruction

1st point

1: Continue

1

0: Block start

2nd point

1: Continue

3

0: Block start

3rd point

0: End

4

0: Block start


Positioning

Data No.

Da.1

Operation pattern

1

01: Continuous positioning control

2

00: Positioning complete

3

00: Positioning complete

4

11: Continuous path control

5

00: Positioning complete


t

1st point: Continue (1)

3rd point: End (0)

2nd point: Continue (1)

Operation
pattern

Continuous path
control (11)

Positioning
data No. 4

Positioning
data No. 5

Positioning complete (00)

Continuous
positioning
control (01)

Positioning
data No. 1

Positioning
data No. 2

Positioning complete (00)

Positioning
data No. 3

Positioning complete (00)

V

Md.48 Deceleration start flag 0

1

Fig. 12.52 Operation of deceleration start flag at block start