Melsec-q, 9 major positioning control remark – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 326

Advertising
background image

9 - 26

MELSEC-Q

9 MAJOR POSITIONING CONTROL

REMARK

•

It is recommended that the "positioning data" be set whenever possible with GX Configurator-QP.
Execution by sequence program uses many sequence programs and devices. The execution becomes
complicated, and the scan times will increase.

Other control

Major positioning control

Positioning data setting items

NOP instruction

Current value

changing

JUMP instruction LOOP instruction LEND instruction

Independent
positioning control

(Positioning complete)

–

–

–

–

Continuous positioning
control

–

–

–

–

Da.1

Operation
pattern

Continuous path
control

–

–

–

–

Da.2

Control system

NOP instruction

Current value

changing

JUMP instruction LOOP instruction LEND instruction

Da.3

Acceleration time No.

–

–

–

–

–

Da.4

Deceleration time No.

–

–

–

–

–

Da.5

Axis to be interpolated

–

–

–

–

–

Da.6

Positioning address/movement
amount

–

Change

destination

address

–

–

–

Da.7

Arc address

–

–

–

–

–

Da.8

Command speed

–

–

–

–

–

Da.9

Dwell time

–

–

JUMP

destination-

positioning data

No.

–

–

Da.10

M code

–

Condition data

No. at JUMP

No. of repetition

–

: Always set

: Set as required ("–" when not set)

: Setting not possible (If setting is made, an error (error code: 515) will occur.)

– : Setting not required (Setting value is invalid. Use the initial values or setting values within a range where no error occurs.)