Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 334

Advertising
background image

9 - 34

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Restrictions

An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning control.

•

If the movement amount of each axis exceeds "1073741824 (=2

30

)" when "0:

Composite speed" is set in " Pr.20 Interpolation speed designation method"
... The "Outside linear movement amount range error (error code: 504)" occurs

at a positioning start.

(The maximum movement amount that can be set in " Da.6 Positioning

address/movement amount" is "1073741824 (=2

30

)".)

Positioning data setting example

[Reference axis is designated as axis 1.]
The following table shows setting examples when "3-axis linear interpolation
control (ABS linear 3)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2 and axis 3.)

Axis

Setting item

Axis 1

(reference

axis) setting

example

Axis 2

(interpolation

axis) setting

example

Axis 3

(interpolation

axis) setting

example

Setting details

Da.1 Operation pattern

Positioning

complete

–

–

Set "Positioning complete" assuming the next
positioning data will not be executed.

Da.2 Control system

ABS linear 3

–

–

Set absolute system 3-axis linear interpolation
control.

Da.3

Acceleration time
No.

1

–

–

Designate the value set in " Pr.25
Acceleration time 1" as the acceleration time
at start.

Da.4

Deceleration time
No.

0

–

–

Designate the value set in " Pr.10
Deceleration time 0" as the deceleration time
at deceleration.

Da.5

Axis to be
interpolated

–

–

–

Setting not required (setting value will be
ignored).

When axis 1 is used as a reference axis, the
interpolation axes are axes 2 and 3.

Da.6

Positioning address/
movement amount

4000.0

µ

m

8000.0

µ

m

4000.0

µ

m

Set the end point address. (Assuming "mm" is

set in "

Pr.1

Unit setting".)

Da.7 Arc address

–

–

–

Setting not required (setting value will be
ignored).

Da.8 Command speed

6000.00
mm/min

–

–

Set the speed during movement to the end
point address.

Da.9 Dwell time

500ms

–

–

Set the time the machine dwells after the
positioning stop (pulse output stop) to the
output of the positioning complete signal.

A

x

is 1 Positioning data N

o

. 1

Da.10 M code

10

–

–

Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.

Advertising