5 - 122

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting item

Setting details

Cd.19

OPR request flag OFF
request

•

The sequence program can use this data item to forcibly turn the OPR request
flag from ON to OFF.

Cd.20

Manual pulse generator 1
pulse input magnification

•

This data item determines the factor by which the number of pulses from the
manual pulse generator is magnified.

•

Value "0"

: read as "1".

•

Value "101" or less: read as "100".

Cd.21

Manual pulse generator
enable flag

•

This data item enables or disables operations using a manual pulse generator.

Cd.22

New torque value

•

When changing the "

Md.35

Torque limit stored value", use this data item to

specify a new torque limit stored value.

•

Set a value within the allowable range of the "

Pr.17

Torque limit setting value".