5 DATA USED FOR POSITIONING CONTROL

5.7.2 Axis control data

Setting item

Setting details

Cd.3

Positioning start No.

•

Set the positioning start No.
(Only 1 to 600 for the Pre-reading start function. For details, refer to Section
12.7.8 "Pre-reading start function".)

Cd.4

Positioning starting point No.

•

Set a " starting point No." (1 to 50) if block start data is used for positioning.
(Handled as "1" if the value of other than 1 to 50 is set.)

Cd.5

Axis error reset

•

Clears the axis error detection, axis error No., axis warning detection and axis
warning No.

•

When the QD75 axis operation state is "in error occurrence", the error is cleared
and the QD75 is returned to the "waiting" state.

Cd.6

Restart command

•

When positioning is stopped for any reason (when axis operation state is

"stopped"), set "1" in

Cd.6

. Positioning will be carried out again from the stopped

position to the end point of the stopped positioning data.

Cd.7

M code OFF request

•

The M code ON signal turns OFF.