Positioning data setting example

[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis circular interpolation
control with sub point designation (INC circular sub)" is set in positioning data No.
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.)

Axis

Setting item

Axis 1

(reference

axis) setting

example

Axis 2

(interpolation

axis) setting

example

Setting details

Da.1 Operation pattern

Positioning

complete

–

Set "Positioning complete" assuming the next positioning
data will not be executed.

Da.2 Control system

INC circular

sub

–

Set incremental system, 2-axis circular interpolation control
with sub point designation.

Da.3

Acceleration time
No.

1

–

Designate the value set in " Pr.25 Acceleration time 1" as

the acceleration time at start.

Da.4

Deceleration time
No.

0

–

Designate the value set in " Pr.10 Deceleration time 0" as

the deceleration time at deceleration.

Da.5

Axis to be
interpolated

1

–

Set the axis to be interpolated (partner axis).

If the self-axis is set, an error will occur.

Da.6

Positioning address/
movement amount

8000.0

µ

m

6000.0

µ

m

Set the movement amount. (Assuming that the "

Pr.1

Unit

setting" is set to "mm".)

Da.7 Arc address

4000.0

µ

m

3000.0

µ

m

Set the sub point address. (Assuming that the "

Pr.1

Unit

setting" is set to "mm".)

Da.8 Command speed

6000.00
mm/min

–

Set the speed during movement. (Designate the composite

speed in " Pr.20 Interpolation speed designation

method".)

Da.9 Dwell time

500ms

–

Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.

A

x

is 1 Positioning data N

o

. 1

Da.10 M code

10

–

Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.

POINT

Set a value in " Da.8 Command speed" so that the speed of each axis does not

exceed the " Pr.8 Speed limit value". (The speed limit does not function for the

speed calculated by the QD75 during interpolation control.)