Melsec-q, 5 data used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 218

Advertising
background image

5 - 130

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting item

Setting details

Cd.36

Step start information

•

During a step operation, this data item determines whether the operation is
continued or restarted.

Cd.37

Skip command

•

To skip the current positioning operation, set "1" in this data item.

Cd.38

Teaching data selection

•

This data item specifies the teaching result write destination.

Cd.39

Teaching positioning data No.

•

This data item specifies data to be produced by teaching.

•

If a value between 1 and 600 is set, a teaching operation is done.

•

The value is cleared to "0" when the QD75 is initialized, when a teaching
operation completes, and when a illegal value (601 or higher) is entered.

Cd.40

ABS direction in degrees

•

This data item specifies the ABS moving direction carrying out the position control
when "degree" is selected as the unit.