5 - 108

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage item

Storage details

Md.41

Special start repetition

counter

•

This area stores the remaining number of repetitions during "repetitions" specific
to special starting.

•

The count is decremented by one (-1) at the loop end.

•

The control comes out of the loop when the count reaches "0".

•

This area stores "0" within an infinite loop.

Md.42

Control system repetition

counter

•

This area stores the remaining number of repetitions during "repetitions" specific
to control system.

•

The count is decremented by one (-1) at the loop end.

•

The control comes out of the loop when the count reaches "0".

•

This area stores "0" within an infinite loop.

Md.43

Start data pointer being

executed

•

This area stores a point No. (1 to 50) attached to the start data currently being
executed.

•

This area stores "0" after completion of a positioning operation.

Md.44

Positioning data No. being

executed

•

This area stores a positioning data No. attached to the positioning data currently
being executed.

Md.45

Block No. being executed

•

When the operation is controlled by "block start data", this area stores a block
number (7000 to 7004) attached to the block currently being executed.

•

At other times, this area stores "0".

Md.46

Last executed positioning

data No.

•

This area stores the positioning data No. attached to the positioning data that was
executed last time.

•

The value is retained until a new positioning operation is executed.

Md.47

Positioning data being

executed

•

The addresses shown to the right store details of the positioning data currently

being executed (positioning data No. given by

Md.44

).

Md.48

Deceleration start flag

•

"1" is stored when the constant speed status or acceleration status switches to the
deceleration status during position control whose operation pattern is "Positioning
complete".

•

"0" is stored at the next operation start or manual pulse generator operation
enable.