7 list of control data, 1 system control data, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 198

Advertising
background image

5 - 110

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.7 List of control data

5.7.1 System control data

Setting item

Setting details

Cd.1

Flash ROM write request

•

Requests writing of data (parameters, positioning data, and block start data) from
the buffer memory to the flash ROM.

•

Requests initialization of setting data.
Initialization: Resetting of setting data to default values

Note: After completing the initialization of setting data, reset the PLC CPU or reboot

the PLC power.

Initialized setting data

Parameters (

Pr.1

to

Pr.57

,

Pr.150

)

Positioning data (No. 1 to No. 600)

Block start data (No. 7000 to 7004)

Cd.2

Parameter initialization request

Cd.41

Deceleration start flag valid

Set whether "

Md.48

Deceleration start flag" is made valid or invalid.

Cd.42

Stop command processing for

deceleration stop selection

•

Set the stop command processing for deceleration stop function (deceleration
curve re-processing/deceleration curve continuation).

Advertising