Codabar, Action, Snmp oid – Intermec 700 User Manual

Page 330: Options

Advertising
background image

Configurable Settings

Appendix

A

306

700 Series Color Mobile Computer User’s Manual

Codabar

Codabar is a self-checking, discrete symbology.

Action

Tap (+) to expand the Codabar parameter, select a setting to be changed,
then select an option from the drop-down list to change this setting.

SNMP OID

1.3.6.1.4.1.1963.15.3.3.1.1.5.1

Options

Decoding

0
1

Not active (default)
Active

Start/Stop

0
1
2
3
4

Not transmitted (default)
abcd transmitted
ABCD transmitted
abcd/tn*e transmitted
DC1–DC4 transmitted

CLSI library system
(Not supported when us-
ing an imager)

0
1

Not active (default)
Active

Check digit

0
1
2

Not used (default)
Transmitted
Not transmitted

Bar code length

0
1
2

Any length
Minimum length (default)
Fixed lengths

Minimum length

003–254

Minimum length 3–254 (default is 6)

Fixed length 1

000–254

Fixed bar code length 0–254 (default is 0)

Fixed length 2

000–254

Fixed bar code length 0–254 (default is 0)

Fixed length 3

000–254

Fixed bar code length 0–254 (default is 0)

Note: If Bar code length = “1” then Minimum length is entered. If Bar
code length
= “2” then Fixed length 1, Fixed length 2, or Fixed length 3
is entered.

Advertising