Imager – Intermec 700 User Manual

Page 362

Advertising
background image

Configurable Settings

Appendix

A

338

700 Series Color Mobile Computer User’s Manual

Imager

Note: These instructions do not apply to the 730 Computer.

To access the settings from the 700 Color Computer, tap Start > Settings
> the System tab > Data Collection to access its control panel applet.

Use the right and left arrows to scroll to the Imager tab, then tap this tab
to access its parameters.

The following are parameters for the imager. Note that these are listed in
the order of their appearance within the Imager tab.

Aimer LED Duration

The Aimer LED Duration controls the time the Aimer LED is turned on
when the scan button is pressed. After this time, images are captured for
decoding. The purpose is to position the Aimer LED on the bar code sym-
bol before attempting to decode the bar code. Note that this is not available
when you use a laser scanner with your 700 Color Computer.

Action

Tap the Aimer LED Duration parameter, then enter a value to change this
setting. Note that values must be in 50 ms increments, such as 500, 650,
or 32500. Values not entered in 50 ms increments are rounded down. For
example, 2489 ms is rounded down to 2450 ms, 149 ms is rounded down
to 100 ms, etc..

SNMP OID

1.3.6.1.4.1.1963.15.3.3.3.1.1.21.1

Options

0–65500 ms (Default is 0)