• When using the HALF-DUPLEX method, the projector can send out a

maximum of 254 bytes of data at once.

• If the response data from an external device does not need to be monitored

and the RESPONSE LIMIT TIME is set to OFF (default), the projector can

receive the data from the computer and send it out to an external device

continuously.

• In case the computer controls to synchronize transmitting and

receiving the data, it may not be able to control an external device well

depending on the processing status of the projector.

NOTE

NOTE

6.4.2 FULL-DUPLEX
This method lets the projector make two way communication, transmitting and

receiving data at the same time, without monitoring response data from an

external device.

When using this method, the computer and external device will send the data out

of synchronization. If it is required to synchronize them, set the computer to make

the synchronization.