5-15

PCK Emulation

To change the scanning mode from Cyclone (factory default) to Smart Raster, use the
following syntax:

Pass Through Scanner Commands

A special "ParamSend" escape sequence is available in the PCK emulation application to
allow "pass through" scanner programming commands. These scanner commands consist
of the "PARAM_SEND" programming group as defined in the Simple Serial Interface (SSI)
Programmer’s Guide
, 72-40451-xx, along with the SE3223 scanner parameter values as
defined in the SE 2223/3223 Scan Engine Integration Guide, 70-36636-xx. The MK1000
"ParamSend" escape sequence, along with the scanner parameter data, allows complete
customization of the scanner’s operational behavior.

Note: Parameter changes can be issued singly or in groups. Group

changes are recommended.

The general format of the ParamSend message is:

<ESC>[255s<0xC6><0x04><0x00><0xFF><Parameter><ParamData>

Where:

<ESC>

= The Escape control character, 0x1B.

[255s

= The MK1000 ParamSend command string.

<0xC6>

= The SSI_PARAM_SEND command byte. Required.

<0x04>

= Data from the host. Required.

<0x00>

= The status byte. The value 0 indicates that this is a temporary parameter

change. You MUST have this and it must be set to zero. Parameter
changes are only effective until the MK1000 is rebooted.

MK1000

Host

<STX><ESC>[1s<ETX> <LRC>

<ACK>

<EOT>