Troubleshooting

3. MK1000 does not send data

to host computer (RS-232
only).

MK1000 is not
programmed to work with
the host.

MK1000 is not connected
to the host.

Check setup communication
parameters.

Check cables to host computer.

5. “Loader Activated...Stand By”

message displays on the
MK1000.

Embedded application
was disabled and no
custom application is
loaded/available to run.

Either:

1) Return to the MK1000
Configuration menu and set the
embedded apps option to enable.

or

2) Load a custom application onto the
MK1000.

6. How do I determine the

MK1000's current OS
version?

(Not applicable)

OS version is displayed on a screen
within the MK1000 Configuration
screens:

- Press the ‘4’ and ‘1’ buttons on the

unit simultaneously (an Enter
Password
screen will appear).

- Type in ‘44213’ (the MK1000

Configuration menu appears).

- With the cursor (<) on System,

press ‘4’ (System Configuration
screen appears).

- With the cursor on Info, press ‘4’

(System Information screen
appears).

- The OS Version is displayed on

the 5th line of the screen.

- If no Info option is available, the

unit has OS version 4.06.05 or
earlier.

(continued)

Table F-1. Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions