F-10

MK1000 MicroKiosk Product Reference Guide

(continued)

MK1000 will not communicate
over a wired-Ethernet
connection.

2. Determine the MK1000’s IP
Address.

- Press the ‘4’ and ‘1’ buttons on the

unit simultaneously (an Enter
Password screen appears).

- Type in ‘44213’ (MK1000

Configuration screen appears).

- Scroll the cursor (<) down to

Network by pressing the ‘3’ button.

- With the cursor on Network, press

‘4’ (Network Configuration screen
appears).

- Scroll the cursor down to Ethernet

by pressing ‘3’ twice.

- With the cursor on Ethernet, press

‘4’ (Ethernet Configuration screen
appears).

- The 4th line shows the MK1000's

wired IP Address - record it on a
sheet of paper.

- The factory default wired IP

Address is 192.168.0.1.

3. Confirm the Wired Ethernet
Setup is ENABLED.

- On the Ethernet Configuration

screen (3rd line), Enabled must =
Yes.

- If Enabled = No, with the cursor

on Enabled, press the ‘4’ button.
Enabled should now = Yes. See
Troubleshooting Note 1.

- Press 1 (Network Configuration

screen re-appears).

(continued)

Table F-1. Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions