6SE6400-5BB00-0BP0

P1503[3]

CI: Torque setpoint

Min: 0:0

CStat:

T

Datatype: U32 Unit:

-

Def:

0:0

P-Group: CONTROL

Active: first confirm

QuickComm.: No

Max: 4000:0

Selects source of torque setpoint for torque control.

Index:

P1503[0] : 1st. Command data set (CDS)
P1503[1] : 2nd. Command data set (CDS)
P1503[2] : 3rd. Command data set (CDS)

Details:

See parameter P1501.

r1508 CO:

Torque

setpoint

Min: -

Datatype: Float Unit:

Nm

Def:

-

P-Group: CONTROL

Max: -

Displays torque setpoint before limitation.

Details:

See parameter P1501.

3.29.2.5 Supplementary torque setpoint

P1511[3]

CI: Additional torque setpoint

Min: 0:0

CStat:

T

Datatype: U32 Unit:

-

Def:

0:0

P-Group: CONTROL

Active: first confirm

QuickComm.: No

Max: 4000:0

Selects source of additional torque setpoint for torque and speed control.

Index:

P1511[0] : 1st. Command data set (CDS)
P1511[1] : 2nd. Command data set (CDS)
P1511[2] : 3rd. Command data set (CDS)

Details:

See parameter P1501.

r1515

CO: Additional torque setpoint

Min: -

Datatype: Float Unit:

Nm

Def:

-

P-Group: CONTROL

Max: -

Displays additional torque setpoint.

Details:

See parameter P1501.

r1518

CO: Acceleration torque

Min: -

Datatype: Float Unit:

Nm

Def:

-

P-Group: CONTROL

Max: -

Displays acceleration torque.

Details:

See parameter P1501.

P1520[3]

CO: Upper torque limit

Min: -99999.00

CStat:

CUT

Datatype: Float Unit:

Nm

Def:

5.13

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 99999.00

Specifies fixed value for upper torque limitation.

P1520

max

P1520

def

r0333

1.5

=

r0333

4

±

=

Index:

P1520[0] : 1st. Drive data set (DDS)
P1520[1] : 2nd. Drive data set (DDS)
P1520[2] : 3rd. Drive data set (DDS)

Level

3

Level

2

Level

3

Level

2

Level

3

Level

2