Issue 01/06

MICROMASTER 440 Parameter List

52

6SE6400-5BB00-0BP0

NEMA Motor

T

1

T

4

T

7

T

3

T

6

T

9

T

8

T

5

T

2

Volts

U

V

W

T

1

-T

7

T

2

-T

8

T

3

-T

9

low

T

4

-T

5

-T

6

T

1

T

2

T

3

high

Connected

together

Connection

T

1

-T

7

T

2

-T

8

T

3

-T

9

Y Y

Y

U

V

W

T

1

-T

6

-T

7

T

2

-T

4

-T

8

T

3

-T

5

-T

9

-

T

1

T

2

T

3

T

4

-T

7

T

5

-T

8

T

6

-T

9

∆ ∆

T

1

T

4

T

7

T

2

T

5

T

8

T

3

T

9

T

6

e.g.: Volts 230 V YY (low) / 460 V Y (high)

Volts

low
high

Connected

together

Connection

P0305[3]

Rated motor current

Min: 0.01

CStat:

C

Datatype: Float Unit:

A

Def:

3.25

P-Group: MOTOR

Active: first confirm

QuickComm.: Yes Max: 10000.00

Nominal motor current [A] from rating plate - see diagram in P0304.

Index:

P0305[0] : 1st. Drive data set (DDS)
P0305[1] : 2nd. Drive data set (DDS)
P0305[2] : 3rd. Drive data set (DDS)

Dependency:

-

Changeable only when P0010 = 1 (quick commissioning).

-

Default value is depending on inverter type and its rating data.


-

Depends also on P0320 (motor magnetization current).

Note:

The maximum value of P0305 depends on the maximum inverter current r0209 and the motor type:

Synchronous motor :

r0209

2

=

P0305

syn

max,

Asynchronous motor :

r0209

=

P0305

asyn

max,


It is recommanded that the ratio of P0305 (rated motor current) and r0207 (rated inverter current) should not
be lower than:

U/f :

SLVC and VC :

r0207

P0305

8

1

r0207

P0305

4

1

P0307[3]

Rated motor power

Min: 0.01

CStat:

C

Datatype: Float Unit:

-

Def:

0.12

P-Group: MOTOR

Active: first confirm

QuickComm.: Yes Max: 2000.00

Nominal motor power [kW/hp] from rating plate.

Index:

P0307[0] : 1st. Drive data set (DDS)
P0307[1] : 2nd. Drive data set (DDS)
P0307[2] : 3rd. Drive data set (DDS)

Dependency:

-

If P0100 = 1, values will be in [hp] - see diagram P0304 (rating plate).

-

Changeable only when P0010 = 1 (quick commissioning).

-

Default value is depending on inverter type and its rating data.













Level

1

Level

1

Advertising