Issue 01/06 parameter description – Siemens 440 User Manual

Page 61

Advertising
background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

61

P0360[3] Main

inductance

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

-

Def:

10.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 3000.0

Sets main inductance [mH] of the motor equivalent circuit (phase value), see diagram below.

1000

0360

P

0310

P

2

L

f

2

L

X

m

m

m

π

=

π

=

ω

=

Main reactance:

Index:

P0360[0] : 1st. Drive data set (DDS)
P0360[1] : 2nd. Drive data set (DDS)
P0360[2] : 3rd. Drive data set (DDS)

Dependency:

Calculated automatically using the motor model or determined using P1910 (motor identification).

Caution:

The data of equivalent circuit relates to the star equivalent circuit. Any data of the delta equivalent circuit
available, therefore must be transformed to the star equivalent circuit before entering into the inverter.

Note:

Cable resistance

0.0 ... 120.0 [Ohm]

P0352.D (0.0)

Stator leak.induct

0.00001 ... 1000.00000

P0356.D (10.00000)

L

σ

S

Rotor leak.induct.

0.0 ... 1000.0

P0358.D (10.0)

L

σ

R

L

m

Main inductance

0.0 ... 3000.0

P0360.D (10.0)

Rotor resistance

0.0 ... 300.0 [Ohm]

P0354.D (10.0)

R

R

On-state voltage

0.0 ... 20.0 [V]

P1825 (1.4)

Gating dead time

0.00 ... 3.50 [us]

P1828 (0.50)

R

S

X

σ

X

m

Γ

R

R

Γ

Cable res. [%]

r0372.D

Stator res. [%]

r0370.D

Tot.leak.react. [%]

r0377.D

Rotor res. [%]

r0374.D

Main reactance [%]

r0382.D

Motor

Cable

Inverter

Stator res. (L2L)

0.00001 ... 2000.00000 [Ohm]

P0350.D (4.00000)

C

R

P0350 = 2(R + R

S

)

Cable

Cable

Cable

R

S

C

R

Cable

Cable

T-equivalent circuit :

L

R

= L

σ

R

+ L

m

L

S

= L

σ

S

+ L

m

equivalent circuit :

i

S

i

R

i

µ

i

S

i

R

Γ

i

µ

Γ

(r0331)

Invers -

Γ

Γ

Γ

Γ

-

Level

4

Advertising