Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

251

P2851 Mode

timer

1

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 13

Selects mode of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.

Possible Settings:

0

ON delay (seconds)

1 OFF

delay

(seconds)

2 ON/OFF

delay

(seconds)

3 Pulse

generator

(seconds)

10 ON delay (minutes)
11 OFF

delay

(minutes)

12 ON/OFF

delay

(minutes)

13 Pulse

generator

(minutes)

Dependency:

P2802[0] is active level for the timer.

r2852

BO: Timer 1

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Displays output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.

Dependency:

P2802[0] is active level for the timer.

r2853

BO: Nout timer 1

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Displays Not-output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.

Dependency:

P2802[0] is active level for the timer.

P2854

BI: Timer 2

Min: 0:0

CStat:

CUT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 4000:0

Define input signal of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.

Dependency:

P2802[1] is active level for the timer.

P2855

Delay time of timer 2

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

-

Def:

0.0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 9999.9

Defines delay time of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.

Dependency:

P2802[1] is active level for the timer.

P2856 Mode

timer

2

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 13

Selects mode of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.

Possible Settings:

0

ON delay (seconds)

1 OFF

delay

(seconds)

2 ON/OFF

delay

(seconds)

3 Pulse

generator

(seconds)

10 ON delay (minutes)
11 OFF

delay

(minutes)

12 ON/OFF

delay

(minutes)

13 Pulse

generator

(minutes)

Dependency:

P2802[1] is active level for the timer.

r2857

BO: Timer 2

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Displays output of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.

Dependency:

P2802[1] is active level for the timer.




Level

3

Level

3

Level

3

Level

3

Level

3

Level

3

Level

3