Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

81

P0708[3]

Function of digital input 8

Min: 0

CStat:

CT

Datatype: U16 Unit:

-

Def:

0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 99

Selects function of digital input 8 (via analog input)

Possible Settings:

0

Digital input disabled

1 ON/OFF1
2

ON reverse /OFF1

3

OFF2 - coast to standstill

4

OFF3 - quick ramp-down

9 Fault

acknowledge

10 JOG

right

11 JOG

left

12 Reverse
13 MOP up (increase frequency)
14 MOP down (decrease frequency)
25 DC brake enable
29 External

trip

33 Disable additional freq setpoint
99 Enable BICO parameterization

Index:

P0708[0] : 1st. Command data set (CDS)
P0708[1] : 2nd. Command data set (CDS)
P0708[2] : 3rd. Command data set (CDS)

Note:

Signals above 4 V are active, signals below 1,6 V are inactive.

Details:

See P0701 (function of digital input 1).

P0719[3]

Selection of cmd. & freq. setp.

Min: 0

CStat:

CT

Datatype: U16 Unit:

-

Def:

0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 67

Central switch to select control command source for inverter.
Switches command and setpoint source between freely programmable BICO parameters and fixed
command/setpoint profiles. Command and setpoint sources can be changed independently.

The tens digit chooses the command source and the units digit chooses the setpoint source.

Possible Settings:

0

Cmd = BICO parameter

Setpoint = BICO parameter

1

Cmd = BICO parameter

Setpoint = MOP setpoint

2

Cmd = BICO parameter

Setpoint = Analog setpoint

3

Cmd = BICO parameter

Setpoint = Fixed frequency

4

Cmd = BICO parameter

Setpoint = USS on BOP link

5

Cmd = BICO parameter

Setpoint = USS on COM link

6

Cmd = BICO parameter

Setpoint = CB on COM link

7

Cmd = BICO parameter

Setpoint = Analog 2 setp

10 Cmd = BOP

Setpoint = BICO parameter

11 Cmd = BOP

Setpoint = MOP setpoint

12 Cmd = BOP

Setpoint = Analog setpoint

13 Cmd = BOP

Setpoint = Fixed frequency

15 Cmd = BOP

Setpoint = USS on COM link

16 Cmd = BOP

Setpoint = CB on COM link

17 Cmd = BOP

Setpoint = Analog 2 setp

40 Cmd = USS on BOP link

Setpoint = BICO parameter

41 Cmd = USS on BOP link

Setpoint = MOP setpoint

42 Cmd = USS on BOP link

Setpoint = Analog setpoint

43 Cmd = USS on BOP link

Setpoint = Fixed frequency

44 Cmd = USS on BOP link

Setpoint = USS on BOP link

45 Cmd = USS on BOP link

Setpoint = USS on COM link

46 Cmd = USS on BOP link

Setpoint = CB on COM link

47 Cmd = USS on BOP link

Setpoint = Analog 2 setp

50 Cmd = USS on COM link

Setpoint = BICO parameter

51 Cmd = USS on COM link

Setpoint = MOP setpoint

52 Cmd = USS on COM link

Setpoint = Analog setpoint

53 Cmd = USS on COM link

Setpoint = Fixed frequency

54 Cmd = USS on COM link

Setpoint = USS on BOP link

55 Cmd = USS on COM link

Setpoint = USS on COM link

57 Cmd = USS on COM link

Setpoint = Analog 2 setp

60 Cmd = CB on COM link

Setpoint = BICO parameter

61 Cmd = CB on COM link

Setpoint = MOP setpoint

62 Cmd = CB on COM link

Setpoint = Analog setpoint

63 Cmd = CB on COM link

Setpoint = Fixed frequency

64 Cmd = CB on COM link

Setpoint = USS on BOP link

66 Cmd = CB on COM link

Setpoint = CB on COM link

67 Cmd = CB on COM link

Setpoint = Analog 2 setp